air curtain ENERGY
Our air curtains conserve energy and improve comfort by limiting
the escape of internal heat, reducing cold drafts and providing a
welcoming down flow curtain of warm air at entrance ways in industrial
plants and store buildings. The resulting mixture of warmed air disperses
gently in all directions at floor level to give uniform temperature over a
wide area from floor to ceiling with only a few degrees difference.
CONVENIENCE
Our air curtains allow personnel and cargo to pass freely from one
area to another while maintaining desired temperatures.
An added safety feature is the free flow of traffic with an unobstructed
view through the opening, eliminating doorway accidents.
TYPICAL USES
Easily mounted over entrance ways of warehouse doors up to 16 feet
high, the air curtains direct an invisible stream of stratified heated air
downward. In addition to adding to employee and customer comfort
during cold weather they provide important energy savings in three ways:
1. In cold weather they reduce the load on heating systems. By drawing
warm air down to floor level where it is needed, our air curtains utilize
the 50% of wasted heated air trapped under ceilings. Stratified air is
mixed and circulated with building heat and heat given off by lights
and machinery, etc.
2. The high velocity curtain of air deflects winds and reduces excessive
heat loss through open doorways.
3. During warm weather they can direct a stream of air downward to
help keep dust, dirt, insects and fumes from entering through open
doorways. If air conditioning exists in the building during warm weather,
the air curtains can be used to prevent loss of conditioned air as well.

Our air curtains create an invisible barrier of high
velocity air to stop cold or warm air infiltrating plant
facilities and work areas.
Stop entry of cold or warm air when doors are
    open.
Prevent the possibility of accidents with unobstructed
   view of passageways.
IMPORTANT: MUST BE INSTALLED ON WARM
SIDE OF DOORWAY OPENING WHEN USED FOR
TEMPERATURE CONTROL
Eliminate need for expensive plastic stripping, flapper
   doors, or canvas curtains.
Cold weather can be further deterred at door opening if
space heater in plant is directed toward intake of the air
curtain.
air curtains
SPECIFICATIONS AND FEATURES
FOR ARCHITECTS AND ENGINEERS EASY INSTALLATION
Our air curtains shall have a self-contained one piece
housing, fire retardant and corrosion proof, in-
corporated with a double extended shaft motor, direct
drive double width and double inlet squirrel cage blower
wheels and fan housings.
Our air curtains are bolted to wall with four fasteners
and connected to electric power source.
AIR VELOCITY CONTROL FOR VARIABLE
AIR SPEED
Adjustable louver damper controls are provided in
order to adjust rate of air flow.
Shall have wedge shaped discharge nozzle containing
adjustable air deflectors with 40% sweep front to back.
When used over a doorway to retain warm or cold
temperature, proper velocity adjustment is imperative
for maximum efficiency. Velocity Control can reduce
air velocity up to 60% with louvers in totally closed
position.
Housing shall be sufficient strength for fastening to wall
on both ends without any intermediate support.
HEAVY DUTY ELECTRIC MOTOR
Continuous duty type motor with double sealed lifetime
pre-lubricated stainless steel ball bearings, resilient
mounted and protected by an automatic thermal overload
switch. Underwriters Laboratories Listed and Canadian
Standards Association Certified. Explosion proof motors
available.
AIR DIRECTIONAL CONTROL
Adjustable vanes at outlet nozzle for directing air
to compensate for possible draft conditions through
doorways.
FIRE RETARDANT AND CORROSION PROOF
How Air Curtain Works
Steel models are of 18 gauge paintlock metal and double
protected with gray, baked, rust preventative electrostatic
polyurethane powder coating.
air curtain
NOISE LEVEL
Our air curtains operate under a low noise level in the
interest and comfort of personnel working in the immediate
vicinity.
air curtains

SELECTION TABLE
APPLICATIONS BARRIER TO
INSECTS, DUST
AND FUMES
CONTAIN BLDG.
AIR HEATED
OR COOLED
FREEZERS
-20° TO +25°
COOLERS
+25° TO +60°
Door widths
up to (ft)
Use this model number DOOR HEIGHT UP TO (FEET)
3 STD 36-1 8 10 10 10
3 1/2 STD 42-1 8 10 10 10
4 STD 48-1 8 10 10 10
5 STD 60-1 8 10 10 10
5 1/3 STD 64-2 8 10 10 10
6 STD 72-2 8 10 10 10
6 1/2 STD 78-2 8 10 10 10
7 STD 84-2 8 10 10 10
8 STD 96-2 OR STD 96-3 8 10 10 10
10 STD 120-3 8 10 10 10
12 STD 144-3 or STD 144-4 8 10 10 10
4 HV 42-1 10 12 12 12
4 1/2 HV 48-1 10 12 12 12
5 HV 60-1 10 12 12 12
6 HV 72-2 10 12 12 12
7 HV 84-2 10 12 12 12
8 HV 96-2 OR HV 96-3 10 12 12 12
10 HV120-2 OR HV 120-3 10 12 12 12
12 HV 144-3 OR HV 144-4 10 12 12 12
14 (2) HV 84-2 10 12 12 12
4 1/2 EP 48-1 14 16 16 16
5 EP 60-1 14 16 16 16
7 EP 84-2 14 16 16 16
8 EP 96-2 14 16 16 16
10 EP 120-2 OR EP 120-3 14 16 16 16
12 EP 144-3 14 16 16 16
14 (2) EP 84-2 14 16 16 16
16 (2) EP 96-2 14 16 16 16
18 EP 96-2 & EP 120-3 14 16 16 16
20 (2) EP 120-2 14 16 16 16
20 (2) EP 120-3 14 16 16 16

air curtain
air curtain

Standard Features:
* All 3 Phase Motor Up
Charges = $75.00 / Motor
1/2 HP Direct Drive Motor Fan Assembly
14" Profile Metal Design Gray Powder Coating
Easy Install
PRICING AND SPECIFICATIONS FOR STANDARD - (UNHEATED MODELS)
MODELS LENGTH FPM AT
NOZZLE
CFM AT
NOZZLE
MOTORS FLA (AMPACITY)
SINGLE PHASE
FLA (AMPACITY)
THREE PHASE
SHIP
WT
(LBS)
PRICE
HP RPM 115V 208V 230V 208V 230V 460V
 STANDARD MODELS
STD 36-1U* 3' 3400 2550 1/2 HP 1750 5.1 2.5/2.5 1.8/1.6 0.8 55 $733
STD 42-1U* 3' 6" 2925 2550 1/2 HP 1750 5.1 2.5/2.5 1.8/1.6 0.8 60 $755
STD 48-1U* 4' 2550 2550 1/2 HP 1750 5.1 2.5/2.5 1.8/1.6 0.8 65 $777
STD 64-2U* 5' 4" 3020 5100 2-1/2 HP 1750 10.2 5.0/5.0 3.6/3.2 1.6 140 $1,177
STD 72-2U* 6' 3475 5100 2-1/2 HP 1750 10.2 5.0/5.0 3.6/3.2 1.6 145 $1,254
STD 78-2U* 6' 6" 3200 5100 2-1/2 HP 1750 10.2 5.0/5.0 3.6/3.2 1.6 150 $1,332
STD 84-2U* 7' 2925 5100 2-1/2 HP 1750 10.2 5.0/5.0 3.6/3.2 1.6 165 $1,376
STD 96-2U* 8' 2550 5100 2-1/2 HP 1750 10.2 5.0/5.0 3.6/3.2 1.6 170 $1,482
STD 96-3U* 8' 3825 7650 3-1/2 HP 1750 15.3 7.5/7.5 5.4/4.8 2.4 200 $1,948
STD 108-2U* 9' 2550 5100 2-1/2 HP 1750 10.2 5.0/5.0 3.6/3.2 1.6 180 $1,543
STD 108-3U* 9' 3400 7650 3-1/2 HP 1750 15.3 7.5/7.5 5.4/4.8 2.4 210 $2,009
STD 120-3U* 10' 3060 7650 3-1/2 HP 1750 15.3 7.5/7.5 5.4/4.8 2.4 225 $2,076
STD 144-3U* 12' 2550 7650 3-1/2 HP 1750 15.3 7.5/7.5 5.4/4.8 2.4 240 $2,253
STD 144-4U* 12' 3400 10200 4-1/2 HP 1750 20.4 10.0/10.0 7.2/6.4 3.2 270 $2,703
*Add Code for required voltage from chart above.
Optional Color Available - Std. Production Color is Battleship Gray
Obsidian Black - $20.00 per linear foot (indicate OB after voltage code)
Pearl White - $20.00 per linear foot (indicate PW after voltage code)
Titanium Silver - $20.00 per linear foot (indicate TS after voltage code)
Spartan Bronze - $20.00 per linear foot (indicate SB after voltage code)
Stainless Steel - $167.00 per linear foot (indicate SS after voltage code)
STANDARD SERIES ACCESSORIES - UNHEATED MODELS
LEVEL 1 - CONTROL PACKAGE - LOW TRAFFIC DOORS
LINE VOLTAGE CONTROL
Part No. Package Price
99-014 Door Limit Switch - Both Plunger & Roller all-in-one 20 amps, up to 250v, up 1 HP $66.60
24 VOLT CONTROL
Part No. Package Price
J0036 Industrial Magnetic Reed Switch with Controller (115v) up to 1 HP Magnetic reed switch with Controller $144.30
J0037 Industrial Magnetic Reed Switch with Controller (208/230v) up to 1 HP Magnetic reed switch
with Controller (RIB)
$144.30
99-081 Industrial Magnetic Reed Switch (only) Used in conjunction with J0036 or J0037 for double doors
or w/control panel
$33.30
99-017 Magnetic Floor Mounted Reed Switch - Used with control panel $77.70
LEVEL 2 - CONTROL PACKAGE - HIGH TRAFFIC DOORS (RECOMMENDED)
24 VOLT CONTROL
Part No. Package Price
J0038 Industrial Magnetic Reed switch, Adj. Time Delay Control (115v) up to 1 HP Magnetic reed switch,
Controller, & Adjustable Time Delay (6 sec-20 min) (RIB)
$177.60
J0042 Industrial Magnetic Reed switch, Adj. Time Delay Control (208/230v) up to 1 HP Magnetic reed switch,
Controller, & Adjustable Time Delay (6 sec-20 min) (RIB)
$177.60
99-081 Additional Industrial Magnetic Reed Switch (only) Used in conjuction with J0038 or J0042 for double
doors or w/control panel
$33.30
J0028 Door Limit Switch, Adj. Time Delay Control (115v) up to 1 HP Door limit switch, controller &
adjustable time delay (6 sec-20 min) (RIB)
$222.00
J0029 Door Limit Switch, Adj. Time Delay Control (2085/230v) up to 1 HP Door limit switch, controller &
adjustable time delay (6 sec-20 min) (RIB)
$222.00
J0039 Magnetic Floor Mounted Reed Switch with Adj. Time Delay (1 sec-17 min) - Used with control panel $222.00
OPTIONAL CONTROLS - Can be paired with any control package (Remote mounted in NEMA 1 J-Box)
Part No. Package Price
99-003 3-Speed Remote Selector Switch - Off/Lo/Med/Hi 15 amps-up to 1/2 HP Single Phase $55.50
99-033 2-Speed Hi/Lo Remote Switch (On/On) 15 amps - up to 1 HP Single Phase $55.50
99-002 3-Speed Hi/Lo Remote Switch (On/Off/On) 25 amps - up to 1 HP Single Phase $94.35

MOTOR CONTROL PANELS-NEMA 1 (Control Panel Configuration)
All 3 Phase Motors or Single Phase combined motors greater than 1 HP, over 250VAC, or greater than 20 amps require a motor
control panel whenever a door limit switch is used to start and stop the air curtain. A door limit switch may be used to directly
control one 1 HP or up to two 1/2 HP single phase motors without the need for a motor control panel (not to exceed 20 amps or 250VAC)
Part No. Description Price
MCPA-1U* One Motor Control Panel 1/2 HP - specify required voltage $455.10
MCPA-2U* Two Motor Control Panel 1/2 HP - specify required voltage $849.15
MCPA-3U* Three Motor Control Panel 1/2 HP - specify required voltage $1,021.20
MCPA-4U* Four Motor Control Panel 1/2 HP - specify required voltage $1,209.90
MCPA-5U* Five Motor Control Panel 1/2 HP - specify required voltage $1,542.90
MCPA-6U* Six Motor Control Panel 1/2 HP - specify required voltage $1,842.60
*Add code for required voltage from chart above.
PANEL ADDERS
Part No. Package Price
94-013 Adjustable Time-Delay (1 sec-17 min) control panel required $194.25
N-FUS Adder for panels with non-fused disconnect $333.00
FUS-30 Adder for panels with fused disconnect up to 30 amps - refer to corresponding submittals $693.75
FUS-60 Adder for panels with fused disconnect up to 30 amps - 60 amps - refer to corresponding submittals $832.50
MCP-MTD Factory Mounted Panel $249.75
MOUNTING BRACKETS
Part No. Mounting Bracket Price
Units have flange on either end for easy overhead or back mounting.
J0016 5" Side Extension Plates - to clear track on either end $77.70/set
J0017 7" Side Extension Plates - to clear track on either end $77.70/set
J0018 9" Side Extension Plates - to clear track on either end $77.70/set
J0004 2 1/2" Clearance Mounting Bracket - to clear wall obstructions $55.50/set
J0005 4" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0006 7" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0007 10" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0008G 10" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0009G 16" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0010G 19" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
J0011G 23" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
*Consult us for vertical mount
FILTERS
Part No. Filters Price
FIL-(size) Aluminum Mesh (1/4") - indicate size in inches $8.88/ft.
*Please cosult us for various flat bank and V bank filters.

air curtain
air curtain
PRICING FOR HIGH VELOCITY SERIES - UNHEATED
MODELS LENGTH FPM AT
NOZZLE
CFM AT
NOZZLE
MOTORS FLA (AMPACITY)
SINGLE PHASE
FLA (AMPACITY)
THREE PHASE
SHIP
WT
(LBS)
PRICE
HP RPM 115V 208V 230V 208V 230V 460V
HV 42-1U* 3' 6" 4570 4000 1 HP 1750 9.0 5.0/5.0 3.3/3.2 1.6 125 $1,088
HV 48-1U* 4' 4000 4000 1 HP 1750 9.0 5.0/5.0 3.3/3.2 1.6 130 $1,099
HV 60-1U* 5' 3200 4000 1 HP 1750 9.0 5.0/5.0 3.3/3.2 1.6 140 $1,121
HV 72-2U* 6' 5140 8000 2-1 HP 1750 18.0 10.0/10.0 6.6/6.4 3.2 300 $2,031
HV 84-2U* 7' 4570 8000 2-1 HP 1750 18.0 10.0/10.0 6.6/6.4 3.2 320 $2,165
HV 96-2U* 8' 4000 8000 2-1 HP 1750 18.0 10.0/10.0 6.6/6.4 3.2 325 $2,220
HV 96-3U* 8' 4600 10000 3-1 HP 1750 27.0 15.0/15.0 9.9/9.6 4.8 405 $2,614
HV 108-2U* 9' 3555 8000 2-1 HP 1750 18.0 10.0/10.0 6.6/6.4 3.2 335 $2,281
HV 108-3U* 9' 4800 12000 3-1 HP 1750 27.0 15.0/15.0 9.9/9.6 4.8 410 $2,686
HV 120-2U* 10' 3200 8000 2-1 HP 1750 18.0 10.0/10.0 6.6/6.4 3.2 350 $2,325
HV 120-3U* 10' 4800 12000 3-1 HP 1750 27.0 15.0/15.0 9.9/9.6 4.8 425 $2,736
HV 144-3U* 12' 4000 12000 3-1 HP 1750 27.0 15.0/15.0 9.9/9.6 4.8 450 $2,925
HV 144-4U* 12' 5140 16000 4-1HP 1750 36.0 20.0/20.0 13.2/12.8 6.4 480 $3,530
*Add code for required voltage from chart above.
Optional Color Available - Std. Production Color is Battleship Gray
Obsidian Black - $20.00 per linear foot (indicate OB after voltage code)
Pearl White - $20.00 per linear foot (indicate PW after voltage code)
Titanium Silver - $20.00 per linear foot (indicate TS after voltage code)
Spartan Bronze - $20.00 per linear foot (indicate SB after voltage code)
Stainless Steel - $167.00 per linear foot (indicate SS after voltage code)
HIGH VELOCITY SERIES ACCESSORIES - UNHEATED
LEVEL 1 CONTROL PACKAGE - Low Traffic Doors
LINE VOLTAGE
Part No. Package Price
99-014 Door Limit Switch - Both Plunger & Roller all-in-one 20 amps, up to 250v, up 1 HP $66.60
24 VOLT CONTROL
Part No. Package Price
99-081 Industrial Magnetic Reed Switch - control panel required $33.30
99-017 Floor Mounted Magnetic Reed Switch - control panel required $77.70
 
LEVEL 2 - CONTROL PACKAGE - High Traffic Doors (RECOMMENDED)
LINE VOLTAGE
Part No. Package Price
J0034 Door Limit Switch with Adjustable Time Delay (1 sec-17 min) panel required $222.00
 
24 VOLT CONTROL
Part No. Package Price
J0040 Industrial Magnetic Reed Switch with Adjustable Time Delay (1 sec-17 min) control panel required $222.00
J0039 Floor Mounted Magnetic Reed Switch with Adjustable Time Delay (1 sec-17 min) control
panel required
$222.00
 
OPTIONAL CONTROLS - Can be paired with any control package (Remote mounted in NEMA 1 J-Box)
Part No. Package Price
99-033 2-Speed Hi/Lo Remote Switch (On/On) 15 amps - up to 1 HP Single Phase $55.50
99-002 2-Speed Hi/Lo Remote Switch (On/Off/On) 25 amps - up to 1 HP Single Phase $94.35
MOTOR CONTROL PANELS-NEMA 1 (Control Panel Configuration)
All 3 Phase Motors or Single Phase combined motors greater than 1 HP, over 250VAC, or greater than 20 amps require a motor
control panel whenever a door limit switch is used to start and stop the air curtain. A door limit switch may be used to directly
control one 1 HP or up to two 1/2 HP single phase motors without the need for a motor control panel (not to exceed 20 amps or 250VAC)
Part No. Description Price
MCPA-1U* One Motor Control Panel 1/2 HP - specify required voltage $455.10
MCPA-2U* Two Motor Control Panel 1/2 HP - specify required voltage $849.15
MCPA-3U* Three Motor Control Panel 1/2 HP - specify required voltage $1,021.20
MCPA-4U* Four Motor Control Panel 1/2 HP - specify required voltage $1,209.90
MCPA-5U* Five Motor Control Panel 1/2 HP - specify required voltage $1,542.90
MCPA-6U* Six Motor Control Panel 1/2 HP - specify required voltage $1,842.60
*Add code for required voltage from chart above
PANEL ADDERS
Part No. Package Price
94-013 Adjustable Time-Delay (1 sec-17 min) control panel required $194.25
N-FUS Adder for panels with non-fused disconnect $333.00
FUS-30 Adder for panels with fused disconnect up to 30 amps - refer to corresponding submittals $693.75
FUS-60 Adder for panels with fused disconnect up to 30 amps - 60 amps - refer to corresponding submittals $832.50
MCP-MTD Factory Mounted Panel $249.75
MOUNTING BRACKETS
Part No. Mounting Bracket Price
Units have flange on either end for easy overhead or back mounting.
J0016 5" Side Extension Plates - to clear track on either end $77.70/set
J0017 7" Side Extension Plates - to clear track on either end $77.70/set
J0018 9" Side Extension Plates - to clear track on either end $77.70/set
J0004 2 1/2" Clearance Mounting Bracket - to clear wall obstructions $55.50/set
J0005 4" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0006 7" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0007 10" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0008G 10" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0009G 16" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0010G 19" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
J0011G 23" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
*Consult us for vertical mount
FILTERS
Part No. Filters Price
FIL-(size) Aluminum Mesh (1/4") - indicate size in inches $8.88/ft.
*Please cosult us for various flat bank and V bank filters.

air curtain
air curtain
PRICING FOR EXTRA POWER MODELS SERIES - UNHEATED
MODELS LENGTH FPM AT
NOZZLE
CFM AT
NOZZLE
MOTORS FLA (AMPACITY)
SINGLE PHASE
FLA (AMPACITY)
THREE PHASE
SHIP
WT
(LBS)
PRICE
HP RPM 115V 208V 230V 208V 230V 460V
EP 48-1U* 4' 4800 4800 3 HP 3450 30.0 16.5/15.0 8.3/7.6 3.8 130 $1,210
EP 60-1U* 5' 3840 4800 3 HP 3450 30.0 16.5/15.0 8.3/7.6 3.8 140 $1,271
EP 72-2U* 6' 6100 9600 2-3 HP 3450 60.0 33.0/30.0 16.5/15.2 7.6 300 $2,387
EP 84-2U* 7' 5485 9600 2-3 HP 3450 60.0 33.0/30.0 16.5/15.2 7.6 320 $2,442
EP 96-2U* 8' 4800 9600 2-3 HP 3450 60.0 33.0/30.0 16.5/15.2 7.6 325 $2,498
EP 108-2U* 9' 4200 9600 2-3 HP 3450 60.0 33.0/30.0 16.5/15.2 7.6 335 $2,592
EP 108-3U* 9' 4800 12800 3-3 HP 3450 90.0 49.5/45.0 24.9/22.8 11.4 410 $3,091
EP 120-2U* 10' 3840 9600 2-3 HP 3450 60.0 33.0/30.0 16.6/15.2 7.6 350 $2,658
EP 120-3U* 10' 5760 14400 3-3 HP 3450 90.0 49.5/45.0 24.9/22.8 11.4 425 $3,164
EP 144-3U* 12' 4800 14400 3-3 HP 3450 90.0 49.5/45.0 24.9/22.8 11.4 450 $3,275
*Add code for required voltage from chart above
Optional Color Available - Std. Production Color is Battleship Gray
Obsidian Black - $20.00 per linear foot (indicate OB after voltage code)
Pearl White - $20.00 per linear foot (indicate PW after voltage code)
Titanium Silver - $20.00 per linear foot (indicate TS after voltage code)
Spartan Bronze - $20.00 per linear foot (indicate SB after voltage code)
Stainless Steel - $167.00 per linear foot (indicate SS after voltage code)
EXTRA POWER SERIES ACCESSORIES - UNHEATED
LEVEL 1 CONTROL PACKAGE - Low Traffic Doors
LINE VOLTAGE
Part No. Package Price
99-014 Door Limit Switch - Both Plunger & Roller all-in-one 20 amps, up to 250v, up 1 HP $66.60
24 VOLT CONTROL
Part No. Package Price
99-081 Industrial Magnetic Reed Switch - control panel required $33.30
99-017 Floor Mounted Magnetic Reed Switch - control panel required $77.70
 
LEVEL 2 - CONTROL PACKAGE - High Traffic Doors (RECOMMENDED)
LINE VOLTAGE
Part No. Package Price
J0034 Door Limit Switch with Adjustable Time Delay (1 sec-17 min) panel required $222.00
 
24 VOLT CONTROL
Part No. Package Price
J0040 Industrial Magnetic Reed Switch with Adjustable Time Delay (1 sec-17 min) control panel required $222.00
J0039 Floor Mounted Magnetic Reed Switch with Adjustable Time Delay (1 sec-17 min) control
panel required
$222.00
 
OPTIONAL CONTROLS - Can be paired with any control package (Remote mounted in NEMA 1 J-Box)
Part No. Package Price
99-033 2-Speed Hi/Lo Remote Switch (On/On) 15 amps - up to 1 HP Single Phase $55.50
99-002 2-Speed Hi/Lo Remote Switch (On/Off/On) 25 amps - up to 1 HP Single Phase $94.35
MOTOR CONTROL PANELS-NEMA 1 (Control Panel Configuration)
All 3 Phase Motors or Single Phase combined motors greater than 1 HP, over 250VAC, or greater than 20 amps require a motor
control panel whenever a door limit switch is used to start and stop the air curtain. A door limit switch may be used to directly
control one 1 HP or up to two 1/2 HP single phase motors without the need for a motor control panel (not to exceed 20 amps or 250VAC)
Part No. Description Price
MCPA-1U* One Motor Control Panel 1/2 HP - specify required voltage $455.10
MCPA-2U* Two Motor Control Panel 1/2 HP - specify required voltage $849.15
MCPA-3U* Three Motor Control Panel 1/2 HP - specify required voltage $1,021.20
MCPA-4U* Four Motor Control Panel 1/2 HP - specify required voltage $1,209.90
MCPA-5U* Five Motor Control Panel 1/2 HP - specify required voltage $1,542.90
MCPA-6U* Six Motor Control Panel 1/2 HP - specify required voltage $1,842.60
*Add code for required voltage from chart above.
PANEL ADDERS
Part No. Package Price
94-013 Adjustable Time-Delay (1 sec-17 min) control panel required $194.25
N-FUS Adder for panels with non-fused disconnect $333.00
FUS-30 Adder for panels with fused disconnect up to 30 amps - refer to corresponding submittals $693.75
FUS-60 Adder for panels with fused disconnect up to 30 amps - 60 amps - refer to corresponding submittals $832.50
MCP-MTD Factory Mounted Panel $249.75
MOUNTING BRACKETS
Part No. Mounting Bracket Price
Units have flange on either end for easy overhead or back mounting.
J0016 5" Side Extension Plates - to clear track on either end $77.70/set
J0017 7" Side Extension Plates - to clear track on either end $77.70/set
J0018 9" Side Extension Plates - to clear track on either end $77.70/set
J0004 2 1/2" Clearance Mounting Bracket - to clear wall obstructions $55.50/set
J0005 4" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0006 7" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0007 10" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0008G 10" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0009G 16" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0010G 19" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
J0011G 23" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
*Consult us for vertical mount
FILTERS
Part No. Filters Price
FIL-(size) Aluminum Mesh (1/4") - indicate size in inches $8.88/ft.
*Please cosult us for various flat bank and V bank filters.

1/2 HP STANDARD UNHEATED MODELS DRAWING
NOTES:
1. This product is designed to comply with the National
    Electric Code (NEC) ETL listed for US & Canada, and
    bear the CE mark.
2. 7/16" mounting holes (4) provided, (2) on each end.
3. All units have a self contained one piece cabinet, fire
    retardant and corrosion proof pain lock metal, double
    protected with baked on gray color rust preventative
    electrostatic polyurethane powder coating.
4. Cabinet has sufficient strength for fastening to wall on
    both ends without intermediate support.
5. Internal J-Box(ex) for electrical wiring.
6. Unit is to be installed such that air flow is unobstructed.
    Air discharge nozzle containing adjustable air directional
    vanes with 40° sweep front to back.
7. Optional motor control panel. Overloads are factory set.
   Standard procedure is to ship panel loose for remote
    mount. Can be factory mounted on either left or right hand
    side of air curtain housing. Please specify.
8. Circuit protection as per NEC by others.
9. Optional microswitch is field installed and is to be wired
      to the control panel. Switch to be mounted such that the
      air curtain turns on as door begins to open.
-2, -3 & -4 designates the number of motors.
*NOTE: Louver assembly size and number varies with length.
Model No. Mounting Centers A Length B
STD 36-1U 35 1/8" 36"
STD 42-1U 41 1/8" 42"
STD 48-1U 47 1/8" 48"
STD 64-2U 63 1/8" 64"
STD 72-2U 71 1/8" 72"
STD 78-2U 77 1/8" 78"
STD 84-2U 83 1/8" 84"
STD 96-2U 95 1/8" 96"
STD 96-3U 95 1/8" 96"
STD 108-2U 107 1/8" 108"
STD 108-3U 107 1/8" 108"
STD 120-3U 119 1/8" 120"
STD 144-3U 143 1/8" 144"
STD 144-4U 143 1/8" 144"
TYPICAL
INSTALLATION
1. Connect supply voltage
    from power panel to control
    panel. (8)
2. Connect wires from motor
    leads in junction box to
    terminals in panel per print.
3. Connect wires from micro
    switch to terminals in
    panel per print.
4. Check rotation of motors
    and switch leads if
    necessary to correct.

1 HP HIGH VELOCITY UNHEATED MODELS DRAWING
NOTES:
1. This product is designed to comply with the
    National Electric Code (NEC) ETL listed for US
    & Canada, and bear the CE mark.
2. 7/16" mounting holes (4) provided, (2) on each end.
3. All units have a self contained one piece cabinet, fire
    retardant and corrosion proof paint lock metal, double
    protected with baked on gray color rust preventative
    electrostatic polyurethane powder coating.
4. Cabinet has sufficient strength for fastening to
    wall on both ends without intermediate support.
5. Internal J-Box(es) for electrical wiring.
6. Units is to be installed such that air flow is
    unobstructed. Air discharge nozzle containing
    adjustable air directional vanes with 40° sweep
    front to back.
7. Optional motor control panel. Overloads are
    factory set. Standard procedure is to ship
    panel loose for remote mount. Can be factory
    mounted on either left or right hand side of air
    curtain housing. Please specify.
8. Circuit protection as per NEC by others.
9. Optional microswitch is field installed and is to
    be wired to the control panel. Switch to be
    mounted such that the air curtain turns on as
    door begins to open.
-2 & -3 designates the number of motors. *NOTE: Louver assembly size and number varies with unit
length.
Model No. Mounting
Centers A
Overall
Length B
HV 42-1U 41 1/8" 42"
HV 48-1U 47 1/8" 48"
HV 60-1U 59 1/8" 60"
HV 72-2U 71 1/8" 72"
HV 84-2U 83 1/8" 84"
HV 96-2U 95 1/8" 96"
HV 96-3U 95 1/8" 96"
HV 108-2U 107 1/8" 108"
HV 108-3U 107 1/8" 108"
HV120-2U 119 1/8" 120"
HV 120-3U 119 1/8" 120"
HV 144-3U 143 1/8 144"
HV 144-4U 143 1/8 144"
TYPICAL
INSTALLATION
1. Connect supply voltage
from power panel to
control panel. (8)
2. Connect wires from
motor leads in junction
box to terminals in panel
per print.
3. Connect wires from
micro switch to terminals
in panel per print.
4. Check rotation of motors
and switch leads if
necessary to correct.

3 HP EXTRA POWER UNHEATED MODELS
NOTES:
1. This product is designed to comply with the
    National Electric Code (NEC) ETL listed for US
    & Canada, and bear the CE mark.
2. 7/16" mounting holes (4) provided, (2) on each end.
3. All units have a self contained one piece cabinet, fire
    retardant and corrosion proof paint lock metal, double
    protected with baked on gray color rust preventative
    electrostatic polyurethane powder coating.
4. Cabinet has sufficient strength for fastening to
    wall on both ends without intermediate support.
5. Internal J-Box(es) for electrical wiring.
6. Units is to be installed such that air flow is
    unobstructed. Air discharge nozzle containing
    adjustable air directional vanes with 40° sweep
    front to back.
7. Optional motor control panel. Overloads are
    factory set. Standard procedure is to ship
    panel loose for remote mount. Can be factory
    mounted on either left or right hand side of air
    curtain housing. Please specify.
8. Circuit protection as per NEC by others.
9. Optional microswitch is field installed and is to
    be wired to the control panel. Switch to be
    mounted such that the air curtain turns on as
    door begins to open.
-2 & -3 designates the number of motors.
*NOTE: Louver assembly size and quantity varies with unit
length.
MODEL
NUMBER
MOUNTING
CENTERS A
OVERALL
LENGTH B
EP48-1U 47 1/8" 48"
EP60-1U 59 1/8" 60"
EP72-2U 71 1/8" 72"
EP84-2U 83 1/8" 84"
EP96-2U 95 1/8" 96"
EP108-2U 107 1/8" 108"
EP108-3U 107 1/8" 108"
EP120-2U 119 1/8" 120"
EP120-3U 119 1/8" 120"
EP144-3U 143 1/8" 144"
TYPICAL
INSTALLATION
1. Connect supply voltage
from power panel to control
panel. (8)
2. Connect wires from motor
leads in junction box to
terminals in panel per print.
3. Connect wires from micro
switch to terminals in panel
per print.
4. Check rotation of motors
and switch leads if necessary
to correct.

TYPICAL INSTALLATION OF METAL AIR CURTAINS
FOR DRUM TYPE ROLL-UP DOORS
air curtains drawings

TYPICAL INSTALLATION FOR VERTICAL LIFT TRACK DOORS
air curtains drawings

TYPICAL INSTALLATION FOR OVERHEAD MOUNTING
air curtains drawings

Air Curtain, Air Curtain Door, Air Curtain Heater, Air Curtains, Air Doors, Door Air Curtains, Heat Curtains, Mars Air Curtain,
Mars Air Door, Warm Air Curtains, and Insect Barrier from your source for material handling equipment.

Back to Product Category
Home - Product Index - Order - Search - Quote- Info - About Us - Services